EMS12684-15 - Silver conductive coating

Created by Nicole Smith, Modified on Wed, 08 Feb 2023 at 01:35 PM by Nicole Smith

USER NOTES 

EMS12684-15 – Silver conductive 18DB70X coating (DG) 

  

EMS Silver Conductive Coating is a highly conductive acrylic paint designed to take conductive paths or reduce electromagnetic or radio frequency interference (EMI/RFI). Because it is a durable acrylic resin, long-term protection from EMI/RFI is assured. It minimizes loss of metallization through rubbing, and by the oxidation resistant silver that slows down conductivity degradation with age. The flake shape helps ensure maximum points of contact to ensure better conductivity. Loss of shielding through paint peeling is unlikely since the acrylic resin system has been UL-tested and shown to adhere to even difficult substrates like AMS and polycarbonates. 

  

The primary application is to provide an excellent conductivity EMI/RFI shielding suitable for harsh environments. It may also act as a conductive base for applications where it is necessary to impart the highest degree of conductivity to a surface. Being non-magnetic, it also offers a low relative permeability that provides reasonable skin depths, which makes it ideal for microwave transmissions applications. 

 

Feature Highlights and Benefits 

  • Environmentally meets RoHS directive for Low-VOC 

  • Stronger adhesion than water-based coatings 

  • Rub-off resistant 

  • Repairable and removable thermoplastic paint system 

  • Tough and durable coat with excellent weatherability 

  • Corrosion resistant coating: Salt-Spray Tested 

  • Meets MIL-STD-883H (Volume Resistivity = 0.0002Ω·cm) 

  • High Surface Conductivity (≥15 Siemen)–Low Surface resistance of 0.066Ω /sq @ 1 mil 

  • Median attenuation 75 dB ±20 dB per 25.4 µm (~1.0 mil) for frequency range of 10 MHz to 18 GHz 

Cure Rates and Shelf Life 

*Dry to Touch (Liquid): 

3 to 5 min  

*Recoat time (Liquid): 

2 min 

Full Cure at room temp.:  

24 hour 

Full Cure at 65°C: 

1 year 

**Storage Temperature Limits: 

-5 to +40°C (+23 to +104°F) 

*Assumes let 1.00:0.75 let down with thinner. 
**The product must stay within storage temperature limits stated. 

 

Service Ranges 

Service Temperature: 

-40 to +120°C (-40 to +248°F)  

***Maximum coverage per 900 ml:

<168 000 cm² (<180ft²) 

***Maximum coverage per US gal: 

<709 000 cm² (<763 ft²) 

 
***Idealized estimate based on a coat thickness of 25 µm (1.0mil) and 65% transfer efficiency. 

 

Principal Components and their CAS Number 

Silver: 

7440-22-4 

Acrylic Resin: 

9003-01-4 

Acetone: 

67-64-1 

Ethanol: 

64-17-5 

Toluene: 

108-88-3 

 

Properties of Cured EMS Conductive Silver Coating 

NOTE: The first coat thickness is typically around 25 µm [1.0 mil]. 

Electric & Magnetic Properties 

Method 

Value 

Volume Resistivity (Tested by an external and independent laboratory using four point probe.) 

Method 5011.5 in MIL-STD-883H 

0.0002 Ω·cm 

Surface Resistance 
:1 x coat @ 1 mil 

square probe 

*Resistance     *Conductance 
0.066 Ω/sq     15S 

:2 x coats @ 2 mil 

" 

0.055 Ω/sq     18S 

:3 x coats @ 2.5 mil 

" 

0.040 Ω/sq     25S 
*NOTE: Surface resistance is given in /sq and the corresponding conductance in Siemens (S or ) 

Magnetic class relative permeability 

  

Diamagnetic (Non-magnetic) <1.0 

Shielding Attenuation 33 µm [1.0 mil] 

  

  

10 to 100 kHz 

IEEE STD 299-1997 

54 dV to 75 dB 

100 kHz to 1 MHz 

" 

50 dB to 65 dB 

1 MHz to 10 MHz 

" 

54 dB to 65 dB 

10 MHz to 100 MHz 

" 

41 dB to 54 dB 

100 MHz to 1 GHz 

" 

35 dB to 67 dB 

1 GHz to 10 GHz 

" 

41 dB to 59 dB 

10 GHz to 18 GHz 

" 

36 dB to 72 dB 

Physical Properties 

Method 

Value 

Resin technology 

 

Lacquer (Thermoplastic) 

Colour 

Visual 

Metallic Silver Grey 

Abrasion resistant 

 

Yes 

Blister resistant 

 

Yes 

Peeling resistant 

 

Yes 

Environmental & Aging Study 

Method 

Value 

Salt Spray Test: 7 day @35 °C +Salt/Fog 

ASTM B117-2011 

  

Cross-hatch adhesion 

ASTM D3359-2009 

5B = 0% area removed 

Cracking, unwashed area 

ASTM D661-93 

None 

Visual Colour, unwashed area 

ASTM D1729-96 

Severe yellowing & discoloration 

Peeling, unwashed area 

ASTM D1729-96 

None 

 

Graph–Silver Coating Surface Resistance at Different Thicknesses 

 

Properties of Uncured EMS Conductive Silver Coating 

Physical Property:  Mixture      Colour: Metallic silver grey 

Density @ 25°C2.15 g/mL 

Solids Percentage (wt/wt) (Percentage for liquid only before thinning)~73% 

Viscosity at 25°C (77F)   (Brookfield viscometer)~8,000 cP 

Flash Point-16°C (3.2°F) 

Odor Ethereal, benzene-like 
 

Compatibility 

Chemica 

The silver filler is very resistant to oxidation, except in environments containing contaminants such as ozone or H2S, which tarnish its surface. Silver oxide remains conductive so degradation due to oxidation is not as bad as it is with many other metal oxides. 
Common paint solvents like acetone, toluene, MEK, and xylene can dissolve the thermoplastic resin. This does make for easier coating repair and work characteristics but is also makes the coating unsuitable for environments that have a lot of solvents. 

Adhesion 

EMS Conductive Silver Paint coating adheres to acrylics, metals, epoxies, wood, ABS, PBT, PC, PU, and PVA. NOTE: It is not compatible with contaminants like water, oil, and greasy flux residues which may affect adhesion. If contamination is present, clean the surface before coating. 

Storage 

Store in a dry area, between -5°C and 40°C (23°C and 104°F). 

 